Power Electronics About Power Electronics Technology | For Advertisers | Contact Us | Subscribe| HOME




Psi or Theta: Which One Should You Choose?

Mar 1, 2008 12:00 PM
By Roger Stout, ON Semiconductor



So, how did JEDEC improve the situation? In my view, the most significant improvement was the definition of some new terms. In particular, farther into JESD51-2, § 4.3 states:

“… The junction-to-top center-of-package thermal characterization parameter, ΨJT, is calculated using the following equation: ΨJT = (TJss - TTss)/ PH. … The relationship between the junction-to-ambient thermal resistance, θJA , and the junction-to-top center-of-package thermal characterization parameter, ΨJT , is described by: θJA = ΨJT + ΨTA , where ΨTA equals thermal characterization parameter from top surface of package-to-air (°C/W). … The thermal characterization parameters, Ψ

It took another decade, but the logical extension of Ψ to other points of interest was codified in 2005, when JEDEC published JESD51-12 “Guidelines for Reporting and Using Electronic Package Thermal Information,” and in which can be found, among other statements:

“… The purpose of the JESD51 standards is to compare the thermal performance of various packages under standardized test conditions. While standardized thermal test information cannot apply directly to the many specific applications, the standardized results can help compare the relative thermal performance of different packages. A more meaningful comparison is possible if the test conditions are understood along with the factors affecting package thermal performance. Brief discussions of key topics are included in this guideline.”

Within the guidelines, it is noted that ΨJB was not included in the natural convection standard because it had not yet been defined, but that it may be added in the future. JESD51-12 further went on to clarify some existing terminology, in particular θJC and θJB:

“The conduction thermal resistances θJCx and θJB are measured with nearly all of the component power dissipation flowing through either the top or the bottom of the package. The values may be useful for comparing packages but the test conditions don't generally match the user's application. … θJCx is the junction-to-case thermal resistance. The ‘x’ indicates the case surface where TCase is measured and through which the heat is forced to flow during the θJCx measurement, ‘top’ for the top surface or ‘bot’ for the bottom surface. … Ideally, during θJCx measurement, close to 100% of the power flows from the junction to the ‘x’ case surface. The θJCx nomenclature is used to avoid the confusion associated with qJC. Historically, the θJC case surface is defined as the ‘outside surface of the package (case) closest to the chip mounting area when that same surface is properly heat sunk.’ This could be either the top or bottom surface, but it is not always clear which surface was used when a θJC value is reported.”

In § 5.2.3 of the JESD51-12 Guidelines, ΨJT and ΨJB thermal characterization parameters are discussed:

“The thermal characterization parameters ΨJT and ΨJB are measured by suppliers at the same time and in the same environments as θJA or θJMA. Users can apply the Ψ equations to estimate the component junction temperature in their application by measuring a component temperature in the application environment and using the appropriate Ψ thermal characterization parameter. This estimated junction temperature can then be compared with a junction temperature specification. A component power estimate is required. … Using ΨJT or ΨJB values together with package top or board temperature measurements in a system requires good temperature measurement technique, comparable to that used when the supplier measured ΨJT or ΨJB. … When a heatsink or added heat spreader is present, neither ΨJT nor ΨJB can be used to estimate the junction temperature. It can be approximated using θJCtop , measuring the heatsink temperature in the application as close to the package interface as possible, and accounting for the temperature difference across the heatsink to case interface. Alternatively, some suppliers may provide a junction-to-sink ΨJS thermal parameter that may be used analogously to ΨJT , recognizing that the ΨJS value is dependent on the package-to-heatsink interface.”

A Closer Examination

Fig. 1 and Fig. 2 introduce a very generic “thermal system” that illustrates what's different between the definitions of θ and Ψ. Referring to Fig. 1, if you can define the path along which heat flows and quantify the heat along that path, only then can you call it θ. With this restriction, it may be seen that the traditional definitions of θJA and θJC are applicable. Regarding θJA, all the heat that can flow must originate at the junction and end up at ambient (even if the path isn't pinned down, at least you know the heat can't sneak away to somewhere not encompassed by the system). Regarding θJC, you can presume that something approaching 100% of total device heat is flowing out through the heatsink, which it is supposed to do. Of course, you have to know what location on the package, exactly, is meant by the word “case” in the specifications.

On the other hand, referring to Fig. 2, if all you can do is measure the total device power and you have no idea of how much of it flows up, down, out the leads or through the air gap (pretty typical in the semiconductor packaging thermal lab), yet you really would like to measure the temperature at one or more points around the boundary of the package (which is actually pretty easy), then you can't call it a θ, but must instead call it a Ψ. Thus, JEDEC's new terms ΨJT , ΨTA, ΨJL and ΨJB are all concessions to the reality that it's easy to measure temperature and really difficult to measure heat flux — especially on miniscule semiconductor devices.

Still, you may be asking, why is this distinction between θ and Ψ so important? Take a look at the simple four-resistor package model shown in Fig. 3. I've used θ's here for the four individual resistors, because I'm defining them to be true thermal path resistances. (In particular, I'm using θJCtop as the true path resistance from the junction to the top of the package, where it's exposed to the air; in a moment, I'll relate it to the original JEDEC-defined ΨJT to represent the characterization parameter to the top center of the plastic case.)

As you see, what I've really done is to create a two-resistor “compact thermal model” of the package, along with two external resistances that digest the entire external system behavior into a very minimal set of parameters.

Taking the system as a whole, the overall thermal resistance, junction to ambient, can be written as follows:

It takes a little more effort, but if you work it out, you'll also be able to derive the following:

What this says, if you think about it, is that even when the two-package thermal resistances are absolutely and truly constant (the two-parameter compact thermal model values θJB and θJCtop), the corresponding Ψ values ΨJB and ΨJC are not constants (unless the overall ratio of the two individual paths happens to remain constant).

To put some meat onto this skeleton, look at Fig. 4, Fig. 5 and Fig. 6. All I've done to generate these graphs is hold θJB and θJCtop constant, and let θBA and θCtopA vary. (For one scenario in each graph, I let the ratio of θCtopA to θBA be fixed — and called the plot “var airflow.” In the other scenario, I held θCtopA constant and allowed θBA to vary by itself — and called the plot “var brd only.”)

Now you might not have as much as three orders of magnitude of possible variation in your particular application board or airflow. But that's not totally outrageous over all possible users and applications of a particular device. The point is that ΨJT , in particular, can easily vary by 300% in a variable airflow situation and by more than 1000% when the board resistance alone changes by a factor of 1000.

Unfortunately, ΨJT is the value very often reported by another name in data sheets in which vendors haven't been careful to define their terms; through oversight or unfamiliarity with the newer JEDEC standards, it might even be called θJC. So if you wondered what that ΨJT parameter meant when you saw it recently, now you know. And if you aren't sure how your device supplier measured and reported its data sheet thermal values, now you should care!

Click here for the enhanced PDF version of this article


April 2008
power electronics technology magazine current issue cover
Advertisement




Thermal Management News

Liquid Cooling Is Coming To Chips and Boards

IGBT Baseplates Feature Low CTEs

Firm Opens Thermal Design-and-Test Facility

Partnership Targets Data-Center Cooling

Cooling Fan Maker Expands Regional Presence

 
Back to Top

Topic Index

Discrete Semis
Bipolar Transistors
IGBTs
Power Modules
Power MOSFETs
Rectifiers/Diodes
Thyristors

Power Management
Digital Power Control
High-Voltage Devices
LED Drivers
Lighting Power Management
Motor Power Management
Power ICs
PWM Controllers
Regulator ICs

Portable Power Management
Batteries
Battery Charger ICs
Fuel Gauges Controllers and Regulators
Micro Fuel Cells

Passives/Packaging
Capacitors
Circuit Protection Devices
Connectors
Magnetics
Packaging
Printed Circuit Boards
Resistors
Sensors & Transducers
Switches & Electromagnetic Relays

Topic Pages
Wind Power
Flyback Transformers

Thermal Management
Fans
Heatpipes & Spreaders
Heatsinks
Liquid Cooling
Thermal Interface Materials
Thermal Management Simulation

Power Systems
DC-DC Converters
Distributed Power Architectures
EMI & EMC
Linear Power Supplies
Safety/Environmental Approvals
Simulation/Modeling
Switch-Mode Power Supplies
Test & Measurement Uninterruptible Power Supplies

Digital Power
Commentaries
Digital Power News
Digital Power Products
Design Features


Contact Us  For Advertisers  For Search Partners  Privacy Policy  Subscribe
© 2007 Penton Media, Inc. All rights reserved.