Five Electrical Safety Compliance Tests in One Box
May 21, 2010 1:28 PM
News & Features From Auto Electronics
Committed to improving hybrid electric cars
New Motors for Hybrid Vehicles
Battery Firms Battle for Hybrid Hegemony
Innovative Bipolar Plates for Fuel Cells
See More Headlines
Top Articles
Exploring Current Transformer Applications
Ultracapacitor Technology Powers Electronic Circuits
Buck-Converter Design Demystified
Sensorless Motor Control Simplifies Washer Drives
PET Resources
Buyer's Guide
Conferences
Engineering Jobs
Power Electronics Events
Rent Our Lists
Spotlight on Digital Power
Chroma Systems Solutions releases the 19032 series Safety Analyzer able to perform five dielectric tests in one unit including AC/DC Hipot, Insulation Resistance, Ground Bond, and optional Leakage Current tests. The time-saving TwinPort™ feature performs Hipot and Ground Bond simultaneously cutting time for these tests in half. The 19032 also has an open / short check function (OSC) that checks for an open connection or a DUT short during testing. Open connections may cause a bad DUT to test OK. Screening for shorts prevents damage to the equipment saving potential costs that may occur. These patented features are only available in safety products manufactured by Chroma.
The 19032 Safety Analyzer performs five test functions suitable for electromechanical and electronic equipment safety standards such as IEC 60601 and 60950. AC Hipot testing allows programmable output voltage from 0.05 to 5kV with cutoff current to 40mA. DC Hipot output voltage is up to 6kV with cutoff current to 12mA. Testing Insulation Resistance (IR), the measurement range of the 19032 is 100Kohm to 50Gohm and test voltage range is 50V to 1000V. Testing Ground Bond (GB), the grounding resistance range measured is up to 510mohm with programmable output current up to 30A standard or 40A with an optional current transformer. If Dynamic Leakage Current (LC) testing is a requirement, Chroma offers various leakage current scanners to meet Medical equipment and other safety standards including Earth, enclosure, patient and patient auxiliary LC tests. These scanners can be installed right into the back of the unit prior to shipment.
The analyzer is equipped with programmable limits for pass/fail testing as well as storage and recall of 50 different test setups with 100 steps per setup. The 19032's generous display panel is more than enough to clearly indicate setting status, time, current, voltage, resistance value, memory number, etc. Also standard are the RS332 and I/O interfaces, however, if GBIP is desired, Chroma makes that available as an option.