SPICE simulation's historical shortcoming of permitting multiple DC operating point solutions for non-linear design, as in control systems, is mitigated by STATESET's furnishing a new circuit branch where the element output is initialized during the entire DC operating point calculation. It linearizes control law equations and can also work in conjunction with GFT modeling to help establish STATESET's initial condition.


Find a downloadable version of this story in pdf format at the end of the story.

A major new “STATESET” SPICE model used in fast average modeling (http://www.intusoft.com/DSP/Average_Models.pdf) for power supplies and related control systems guarantees DC convergence for nonlinear circuits. Many nonlinear circuits have more than one stable operating point solution during SPICE simulation, which uses the “nodeset” statement to suggest an initial value. However, the suggestion must be released when the simulator starts doing iterations in order to account for the branch currents. STATESET, on the other hand, creates a new circuit branch in which the element output is initialized during the entire DC operating point calculation. Once the operating point is calculated, the input of the STATESET branch connects to its output so the AC and Transient analyses can proceed. STATESET is essentially a gain element that has two terminals, input and output, where a signal flows from the input to the output in a control-system fashion.

Though STATESET is a simple concept, standard SPICE simulators can't handle the problem STATESET resolves. Users of XSPICE-enabled simulators can easily add a code model (http://www.intusoft.com/best.htm) that achieves the desired result. Other SPICE simulators (Pspice and Hspice) need to add a new primitive element.

STATESET UNVEILED

One of the most daunting non-linearities is the “Middlebrook” equation [1] that describes a peak current controller as a function of average current at its terminal voltages. This equation has more than one stable solution, which can cause the SPICE DC operating point solution to become unstable, and therefore unable to converge.

A linear pulse width modulator (PWM) average model sets output voltage and input current to functions of the input duty ratio. The simplest of all models results when the switched inductor current is continuous, referenced as continuous conduction mode (CCM). The process is governed by Z-Transform theory, requiring a zero-order hold and a limiter to constrain the duty ratio between 0 and 1. The current and voltage functions are nonlinear, but they can be made linear for the DC solution by using a STATESET element shown in Fig. 1.

Normally the duty ratio will depend on the output of a controller that senses the output current and voltage. The control law typically depends on the input and output voltage, making the overall solution nonlinear. But the STATESET element uses a constant for the duty ratio during calculation of the DC operating point, which effectively makes the system of equations linear. This guarantees a unique solution.

The switch representation in Fig 2 is used to make a model that relies on the superposition of the solutions for the three switch positions.

For superposition to work, the driving point impedances for each position cannot be affected by the switch position. If that's true, then:

and

SWITCH MODE POWER SUPPLY EXAMPLES

The buck regulator in Fig. 3 is used to reduce the input voltage. The D 1 switch is driven and the D2 switch is constructed using the freewheeling diode. In continuous conduction mode (CCM), D3 = 0. As the load current is reduced, the regulator drops into discontinuous conduction mode (DCM), and D3 is greater than 0.

Shown in Fig. 4 is a boost model circuit used to increase the input voltage, reversing V o and Vin. Switch D2 is driven and the freewheeling diode goes into the D1 switch position.

You can calculate peak inductor current based on the measured average value of the current, duty ratio and inductor voltage. Solving for the duty ratio results in the Middlebrook equation [1], referenced above.

Where:

VC = Control input

RB = Current sense resistor

Vramp = Ramp compensation

Fig.5 shows how STATESET is able to get the “inner loop” transfer function for a peak current controlled SMPS that uses the Middlebrook equation to define duty ratio. This intrinsic loop has previously not yet been studied. However, using GFT theory, a single injection loop cut was made (http://www.intusoft.com/lit/GFTSummary.pdf) just after the V avg signal. The resulting Bode plot exposes the high duty ratio instability of peak current control. Fig. 6 is the phase margin verses duty ratio resulting from the GFT analysis.

Solving for average current as a function of duty ratio yields:

Di is the initial duty ratio and is used to remove offset, centering the output at the controlled value. That's the value used for the STATESET initial condition.

The following average models that use STATESET are available from Intusoft for Buck, Boost and Buck/Boost(CCM):

  • Peak current control
  • Average current control
  • Duty ratio control

The Buck, Boost and Peak Current Control models represent a new method to extend the voltage control model of Meares and Bello [2] from the CCM case, to the non-linear case where the controller can switch between CCM and DCM modes. Previously, the switching caused DC convergence failure in SPICE due to Middlebrook's equation having an implicit quadratic solution with two stable states. STATESET solves this problem by eliminating the need to solve the nonlinear equation during the DC operating point calculation.

USING STATESET WITH INITSWITCH

Fig.7 illustrates the use of the aforementioned new models to set up the operating point for a Buck regulator model. The model uses the Middlebrook equation to convert average current to duty ratio in a peak current controller. Without these elements, the DC operating point is unstable, precluding the AC analysis needed to predict stability margins. These elements were developed following Intusoft's study of digital control design and analysis using the IsSpice4 simulator. The new Z_DELAY element initialized its output, thus breaking the feedback loop in solution of the DC Operating point.

REFERENCES:

Download the story in pdf format here.


Acceptable Use Policy blog comments powered by Disqus




April 1, 2012
power electronics technology magazine current issue cover
Advertisement




Power Systems News

Broad Range of EMI Filters

Industry's Smallest Integrated Power Stage (iPSTM)

New Jersey Utility to Build 120MW of Solar Capacity

XP Vehicles Expects U. S. DOE ATVM Funding to Complete Development of Revolutionary Electric Vehicle

Triple Output 500W Medical Grade Power Supplies

 
Back to Top

Topic Index

Discrete Semis
Bipolar Transistors
IGBTs
Power Modules
Power MOSFETs
Rectifiers/Diodes
Thyristors

Power Management
Digital Power Control
High-Voltage Devices
LED Drivers
Lighting Power Management
Motor Power Management
Power ICs
PWM Controllers
Regulator ICs

Portable Power Management
Batteries
Battery Charger ICs
Fuel Gauges Controllers and Regulators
Micro Fuel Cells

Passives/Packaging
Capacitors
Circuit Protection Devices
Connectors
Magnetics
Packaging
Printed Circuit Boards
Resistors
Sensors & Transducers
Switches & Electromagnetic Relays

Topic Pages
Wind Power
Flyback Transformers

Thermal Management
Fans
Heatpipes & Spreaders
Heatsinks
Liquid Cooling
Thermal Interface Materials
Thermal Management Simulation

Power Systems
DC-DC Converters
Distributed Power Architectures
EMI & EMC
Linear Power Supplies
Safety/Environmental Approvals
Simulation/Modeling
Switch-Mode Power Supplies
Test & Measurement Uninterruptible Power Supplies

Digital Power
Commentaries
Digital Power News
Digital Power Products
Design Features


Contact Us  E-mail Webmaster  For Advertisers  For Search Partners  Privacy Statement  Subscribe  Terms of Use
© 2011 Penton Media, Inc. All rights reserved.