Topology Selection By the Numbers Part Two
Apr 1, 2006 12:00 PM
By Ernie Wittenbreder, Chief Engineer, Technical Witts, Flagstaff, Ariz.
In this second part of a three-part series, we consider some of the alternatives to the bucks and boosts discussed in part one for nonisolated stepup and stepdown conversion for situations in which there may be better choices.
News & Features From Auto Electronics
Committed to improving hybrid electric cars
New Motors for Hybrid Vehicles
Battery Firms Battle for Hybrid Hegemony
Innovative Bipolar Plates for Fuel Cells
See More Headlines
Top Articles
Exploring Current Transformer Applications
Ultracapacitor Technology Powers Electronic Circuits
Buck-Converter Design Demystified
Sensorless Motor Control Simplifies Washer Drives
PET Resources
Buyer's Guide
Conferences
Engineering Jobs
Power Electronics Events
Rent Our Lists
Spotlight on Digital Power
For a PDF verion of this article, click here.
In part one of this article series, we found that total component stress factors (CSFs) — a new analysis method that enables the comparison of different power conversion topologies — for buck and boost converters were the same for fixed-line voltage where the stepdown ratio of the buck converter was equal to the stepup ratio of the boost converter. In this second part, we focus on nonisolated applications with limited line-voltage range.
Buck and boost converters are part of the same canonical cell where the differences between the buck circuit and the boost circuit are the line and load connections. We illustrate this relationship in Fig. 1 where the circuit operates as a buck converter for power flow from left to right and as a boost converter for power flow from right to left.
Instead of treating the stepup and stepdown problems separately, we recognize that a stepup converter is a stepdown converter that operates with power flow reversed. Therefore, any of the circuits in this second part of the article series can be operated either as stepup or stepdown. In every case, power flow from left to right will correspond to stepdown conversion, and power flow from right to left will correspond to stepup conversion.
In part one, we found that the lowest CSFs for the buck converter occurred for stepdown ratios near 1 and that the lowest CSFs for the boost converter occurred for stepup ratios near 1. We will consider the problem where the stepup or stepdown ratio is near but not equal to 1, as well as some alternatives to simple bucks and boosts.
Fig. 2 illustrates a tapped-inductor buck or boost, which is an attractive candidate for small stepup and stepdown ratios. The only difference between this converter and the simple buck and boost of Fig. 1 is the second winding of the choke placed in series with the lower MOSFET (M
For Fig. 2, there will be a different set of CSFs for each turns ratio, and the turns ratio can be varied to achieve different results. We will consider the case where the load/line at the right side of the circuit is 380 V and the line/load at the left side of the circuit is 400 V at a power level of 400 W. We also will consider the minimum-voltage tapped-inductor converter
The Fig. 3 circuit is of minimum voltage in the sense that none of the transistors has voltage stress higher than the load/line voltages. Refer to part one of this article series for information on how to calculate the CSF for each component. Table 1 summarizes optimized results for Figs. 1, 2 and 3.
For the Fig. 2 circuit, if we optimize component weights for minimum total semiconductor component stress factor (SCSF), we find that the optimal turns ratio is 17.9 and we achieve a 20 times reduction in total semiconductor stress but at a cost. With a 17.9 turns ratio, the total winding component stress factor (WCSF) has almost doubled and the capacitor component stress factor (CCSF) has increased by almost two orders of magnitude.
In many applications, this may be a good tradeoff since the input capacitor requirement may be driven by an electromagnetic interference filter requirement or an interface stability issue, such as Middlebrooke's rule, and the output capacitor requirement may be driven by a load transient or ripple voltage requirement.
Table 2 also illustrates a compromise case where the turns ratio is selected to be 1-to-1. With a 1-to-1 turns ratio, a substantial improvement in total SCSF is realized with more modest degradations in total WCSF and total CCSF. The lower semiconductor component stresses are achieved by using a low-voltage MOSFET for M
With a 17.9 turns ratio, M
| Figs. 1 and 2 Turns ratio = 0 | Fig. 2 Turns ratio = 17.9 | Fig. 2 Turns ratio = 1 | Fig. 3 Turns ratio = 11.1 | |
|---|---|---|---|---|
| M |
1.29 | 0.04 | 0.4 | 0.036 |
| M |
0.3 | 0.038 | 0.12 | 0.019 |
| M |
0 | 0 | 0 | 0.021 |
| Total SCSF | 1.59 | 0.078 | 0.52 | 0.076 |
| L |
0 | 0.01 | 0.01 | 0.007 |
| L |
0.01 | 0.009 | 0.002 | 0.005 |
| Total WCSF | 0.01 | 0.019 | 0.012 | 0.012 |
| C |
0.053 | 1.89 | 0.16 | 3.01 |
| C |
0 | 1.7 | 0.07 | 2.76 |
| C |
0 | 0 | 0 | 0.15 |
| Total CCSF | 0.053 | 3.59 | 0.23 | 5.92 |
| Figs. 1 and 5 Turns ratio=0 | Fig. 4 Turns ratio=5 | Fig. 5 Turns ratio=9.14 | Fig. 5 Turns ratio=3 | Fig. 6 Turns ratio=5 | |
|---|---|---|---|---|---|
| M |
40 | 1.61 | 13.4 | 13.7 | 6.4 |
| M |
120 | 2.96 | 12.6 | 20.6 | 11.8 |
| M |
0 | 1.64 | 0 | 0 | 6.5 |
| Total SCSF | 160 | 24.8 | 26.1 | 34.3 | 24.8 |
| L |
0 | 0.4 | 2.9 | 1.7 | 1.6 |
| L |
3.24 | 0.56 | 3 | 3.4 | 2.24 |
| Total WCSF | 3.24 | 3.84 | 5.9 | 5.1 | 3.84 |
| C |
9 | 0.39 | 1.7 | 2.9 | 2.3 |
| C |
0 | 0.48 | 1.5 | 0.9 | 2.9 |
| C |
0 | 0.48 | 0 | 0 | 2.9 |
| Total CCSF | 9 | 1.35 | 3.3 | 3.8 | 8.1 |
One way to solve this problem is by keeping M
For a topology that has superior total SCSF and superior total WCSF, a high CCSF can be dealt with by employing an interleaved multiphase configuration. Paralleling multi-phase subconverters has no effect on total SCSF or total WCSF, but multiphasing reduces total CCSF by a factor equal to or greater than the square of the number of parallel subconverters (Fig. 4).
In the Fig. 3 circuit, M
Another problem where candidate topologies exist that compete well with simple bucks and boosts is the problem of large step ratios. We consider the problem of stepping from 100 V to 1000 V and from 1000 V to 100 V in a 100-W converter. We will not consider the effects of wide line-voltage variations at this time. The candidate topologies that we will consider are the buck and boost of Fig. 1, the tapped-inductor buck and boost for large step changes (Fig. 5), the minimum-voltage tapped-inductor buck and boost for large step changes (Fig. 6) and a multiphase implementation of the Fig. 6 circuit in which two parallel subconverters share the same set of three capacitors, illustrated in Fig. 4.
Table 2 illustrates the results achieved. The simple buck and boost converters of Fig. 1 have high SCSFs because the switches have both high voltage stress and high current stress. In the Fig. 5 circuit optimized for minimum total SCSF, M
The Fig. 6 circuit achieves slightly lower total SCSF than the Fig. 5 circuit and significantly lower WCSF, only about 20% higher than the simple buck and boost, but the total CCSF is only slightly lower than the Fig. 1 circuit and significantly higher than the tapped-inductor circuit of Fig. 5. In the Fig. 6 circuit, the voltage stresses of M
We use the rules presented in part one of this article series to calculate the total SCSF and total WCSF for the dual subconverter combination. Since we only have one set of capacitors, we must calculate CCSFs for each capacitor again, considering that the capacitor currents are a combination of currents from the two subconverters. Fortunately, the capacitor currents from the two subconverters cancel each other to a large extent due to the fact that the subconverters are operated 180° out of phase. For the MOSFET M
By optimizing for minimum total SCSF, we find that the optimal weight for M
For M
where W
In this case:
For the combination of subconverters the total SCSF is:
which is the same result we had for Fig. 6. We would expect there to be no advantage or disadvantage to breaking the converter into two parallel subconverters — each operating at half power — and the calculated total SCSF confirms that fact.
For L
The RMS current in L
The weight assigned to L
For L
which is identical to the total WCSF obtained for the single-phase circuit, as expected.
Finding the total CCSF for the Fig. 4 circuit presents a different problem, because the three capacitors shown in Fig. 4 are shared by two subconverters. We calculate each CCSF considering that the capacitor currents are formed by algebraic sums of currents from the two subconverters. We assume that subconverter 1 is beginning its operating cycle and subconverter 2 is halfway through its operating cycle.
The average line/load current is P/V
During the next phase of the operating cycle, with duty cycle equal to 0.099, M
For C
With sets of operating equations for candidate circuit topologies and a spreadsheet or other mathematical computation program, one can readily generate a set of numbers for numerical topological comparison using the CSF method. An Excel spreadsheet illustrating the calculations in this article is available at www.TechnicalWitts.com. Next month, in the third and final part of this article series, we will compare isolated topologies and consider the effects of wide line-voltage range on power converters.
References
Wittenbreder, E.H., “Tapped Inductor Power Conversion Networks,” U.S. Patent Application 60/757561. Available online at www.technicalwitts.com.