Modeling DC-DC Converter Transient Response
Aug 1, 2004 12:00 PM
By David Morrison, Editor, Power Electronics Technology
|
|
Click here for the enhanced PDF version of this article
News & Features From Auto Electronics
Committed to improving hybrid electric cars
New Motors for Hybrid Vehicles
Battery Firms Battle for Hybrid Hegemony
Innovative Bipolar Plates for Fuel Cells
See More Headlines
Top Articles
Exploring Current Transformer Applications
Ultracapacitor Technology Powers Electronic Circuits
Buck-Converter Design Demystified
Sensorless Motor Control Simplifies Washer Drives
PET Resources
Buyer's Guide
Conferences
Engineering Jobs
Power Electronics Events
Rent Our Lists
Spotlight on Digital Power
Decoupling and bulk capacitance are used to limit the voltage deviation of dc-dc converters in the face of load steps. Yet, requirements for high power density and low cost often dictate that the amount of external capacitance be minimized. One way to do this is by modeling the response of the dc-dc converter to estimate its overshoot/undershoot and settling time in response to predicted load steps. In “Predicting Load Transient Response of Output Voltage in DC-DC Converters,” presented at this year's Applied Power Electronics Conference, Cahit Gezgin of Tyco Electronics Power Systems describes how a converter's transient response may be modeled using a second-order RLC circuit with values from measured voltage loop data (Fig. 1).
For a given load step, the voltage deviation predicted by the model closely approximates actual measured values. This technique also shows that transient response requirements can be met with lower values of capacitance than predicted by calculations of a converter's target impedance. That parameter (Z
To create the model, the values of the RLC components are chosen so the converter in question and the RLC circuit exhibit the same voltage undershoot and settling time in the face of a 5-A load step. The circuit is then used to obtain a first-order approximation of the converter's ΔV and settling time under a load transient.
The author first determines the dynamic response of the RLC circuit to a load step, deriving the following equations for voltage deviation (ΔV) and settling time (T):
where Q
where Q
where Q
The author then creates the macro model of the dc-dc converter shown in Fig. 2, which is related to the RLC circuit in terms of Q
(where Ф
To determine Q
With this approach, the results obtained for ΔV reflect performance at the sense location rather than the load. Also, an infinite current slew rate is assumed. However, this approach will accurately determine ΔV for current slew rates greater than 1 A/µs, when used to test the performance of isolated dc-dc converters with crossover frequencies below 10 kHz. For more information, contact the author at cahit.gezgin@tycoelectronics.com
For more information on this article, CIRCLE 360 on Reader Service Card