Scaling Design Methods To Improve Transformers
Oct 1, 2005 12:00 PM
By Victor W. Quinn, Chief Technology Officer, Tabtronics Inc., Geneseo, N.Y.
Intuitive design techniques based on normalized loss and energy densities demonstrate real benefits for optimizing transformer configurations.
News & Features From Auto Electronics
Committed to improving hybrid electric cars
New Motors for Hybrid Vehicles
Battery Firms Battle for Hybrid Hegemony
Innovative Bipolar Plates for Fuel Cells
See More Headlines
Top Articles
Exploring Current Transformer Applications
Ultracapacitor Technology Powers Electronic Circuits
Buck-Converter Design Demystified
Sensorless Motor Control Simplifies Washer Drives
PET Resources
Buyer's Guide
Conferences
Engineering Jobs
Power Electronics Events
Rent Our Lists
Spotlight on Digital Power
For the PDF version of this article, click here.
The size, performance and cost of a power electronic system are closely linked to the like parameters of the magnetic components. Since custom power transformers are widely used, transformer design is a frequent design process that has a significant impact on system performance. Yet most high-frequency transformers use less than 25% of the available core window for efficient current conduction. Two factors cause this relatively poor utilization: insulation requirements and eddy current losses.
Insulation requirements generally limit the total winding conductor cross-sectional area to less than half of the available core window. Induced high-frequency eddy currents often increase the apparent winding resistances by 50% or more. Therefore, less than 25% of the available core window is used effectively (Fig. 1). Interleaved windings, multifilar conductors, Litz wire and other approaches can decrease eddy current effects. However, these techniques add additional insulation penalties, which further reduce the net cross-sectional window area available for the winding conductors.
Despite much published literature concerning the evaluation of transformer loss and energy at high frequencies, continued widespread interest in transformer design methods indicates that many designers seek more intuitive techniques to evaluate tradeoffs and assure an optimal configuration. This interest is understandable because many methods lead the designer to make repeated trial configurations until obtaining a satisfactory result. While Finite Element Analysis (FEA) and commercial software facilitate the evaluation of many trial configurations, the designer's imagination of improved configurations is fueled by understanding and insight.
A transformer design approach using normalized loss and energy densities inspires concepts of equivalent winding thicknesses that intuitively display optimal conductor and interleaving configurations.
Low-Frequency Transformer Design
Classical transformer design methods evaluate the potential volt-ampere (VA) capacity of a selected core in comparison to the VA requirement of a given power supply application. The VA capacity of a selected core is fundamentally limited by a consideration of losses with respect to temperature rise or efficiency requirements. At low frequencies, currents within conductors are largely uniform throughout the conductors' cross-sections. Therefore, dissipation for a given winding is readily calculated using the material resistivity and the geometric parameters of length and cross-section for the conductor. At low frequencies, for coils with multiple windings having uniform mean lengths of turn, minimum total loss is achieved by selecting appropriate conductors for each winding to yield uniform current density throughout the coil. For uniform resistivity, mean length of turn and current density, the low-frequency dissipation of a coil is given by:
Low-frequency coil loss =
where ρ is the conductor resistivity, Cond
Low-frequency loss can be rewritten using the concept of normalized resistance:
where Ω is the resistance of a theoretically equivalent single-turn winding yielding the specified total Cond
The single-turn resistance Ω is given by the expression:
where Δy is the effective conductor length (or mean length of turn), Δx is the conductor width, and Thickness is the conductor thickness (Fig. 2). The denominator of this expression is equivalent to the total conductor cross-sectional area.
Therefore, low-frequency coil loss can be readily estimated using the normalized single-turn resistance Ω and the square of the sum of the RMS amp-turn products for all windings in the coil. The accuracy of this loss estimate depends on the accuracy of the estimate for the total conductor cross-sectional area. Insulation considerations generally limit the conductor area to less than half of the available core window area. The dominant insulations are those that isolate windings from core (bobbin), windings from other windings (interwinding) and layers from other layers (interlayer). The conductor thickness of the normalized winding can be estimated by reducing the available core window height by the anticipated bobbin, interwinding and interlayer thicknesses.
This approach may be extended to low-frequency magnetic energy in the coil. For a normalized, nonmagnetic, single-portion primary conductor, having uniform mean length of turn and uniform current density, the low-frequency magnetic energy is:
Normalized low-frequency magnetic energy =
where µ
While coil insulation increases loss by decreasing the effective thickness of the conductor for the normalized winding, coil insulation increases magnetic energy in the portion by increasing the effective thickness of coil regions subject to magnetic-field penetration:
Normalized low-frequency magnetic energy =
where Thickness
Low-frequency magnetic energy =
For a specific application and a transformer having given conductor and core regions, the normalized expression for low-frequency winding loss can be combined with an empirically derived core loss result to yield:
Total low-frequency transformer loss =
where F
Therefore, low-frequency transformer design involves normalized empirical core loss data and estimation of effective total conductor volume considering insulation, clearances, electrostatic shields and other coil cross-sectional area penalties.
High-Frequency Transformer Design
High-frequency power electronic applications cause added transformer design considerations. Coil loss is significantly affected by induced eddy currents within the conductors as a result of magnetic-field intensities. Further, high-frequency excitation and circuit topology requirements generate constraints on leakage inductance (stray magnetic energy). The inherent complex waveshapes necessitate consideration of dc and higher-order harmonic components.
For a single-conductor layer, having one conductor surface at zero magnetic-field intensity, high-frequency conductor loss and magnetic-energy storage can be calculated using the concept of dimensionless density functions
Conductor layer power =
Conductor layer magnetic energy =
where δ is the skin depth for the conductor material at the specified frequency, Δx represents the width of the conductor layer, Δy represents the mean length of turn of the conductor layer, R is the ratio of sinusoidal surface magnetic-field intensities, B is the ratio of conductor thickness to skin depth, and p
Although p
Nonsinusoidal Currents
Transformer winding current may contain a bias component, and in this event, the winding current can be represented by the harmonic decomposition:
where I
The equivalent loss-density function for a given layer is then given by:
where B
Similarly, the equivalent ac magnetic-energy density function for a given layer is:
These equivalent density functions can be used to derive expressions for loss- and energy-equivalent conductor thicknesses:
Loss-equivalent thickness =
Magnetic-energy-equivalent thickness =
where n
Although the expressions for loss and magnetic energy invoke complex density terms that appear formidable, let's turn our attention to simple graphical methods using concepts of effective normalized winding thickness and normalized winding height. These concepts are readily accomplished using common computer methods and facilitate graphical recognition of optimal coil designs considering insulation and eddy current penalties.
Equivalent Thickness Methods
As described earlier, the transformer design process involves the calculation of coil loss in consideration of a VA requirement arising from circuit application conditions. For low frequencies, the total coil loss can be evaluated using the product of the single-turn resistance of a volume-equivalent single-turn conductor and the square of the amp-turn product through the conductor cross-section. We will seek a similar intuitive calculation method for loss and magnetic energy in a winding portion undergoing complex excitation.
To this end, we will develop a graphical relationship between the effective winding thicknesses and the physical utilization of an available winding height. This graphical approach facilitates the selection of optimal layers and winding interleaves, including the effects of layer-insulation thickness and considering constraints of maximum leakage-inductance energy and maximum coil height. Loss and magnetic energy can then be evaluated following the expressions for low frequency applied to a normalized conductor having the appropriate equivalent thickness.
This method is illustrated in Figs. 4 through 9 as applied to a winding portion with maximum overall winding thickness of six skin depths, five conductor layers maximum, and interlayer- and interwinding-insulation thicknesses of half a skin depth each. Figs. 4 and 5 pertain to the primary winding of a transformer used in a bridge configuration operating at 62.5% duty cycle. The current was normalized to yield unity RMS value.
Fig. 4 shows that maximum loss-equivalent-winding thickness is achieved when 88% of the winding height is used with five conductor layers. For this configuration, the loss-equivalent-winding thickness is 28% of the available winding height. However, as a result of magnetic energy stored in insulation regions, the corresponding magnetic-energy-equivalent-winding thickness is 92% of the available winding height (Fig. 5). Interleaving effects can be readily evaluated by considering constructions that fit within a fraction of the available winding height. For example, a simple interleave of two portions can be examined by considering winding configurations that fit within half of the available winding height.
In Fig. 4, when winding height is limited to 50%, two layers provide a maximum equivalent thickness of 20%. However, two portions can be used with an interleave strategy to double the equivalent winding thickness and in this case achieve 40% of the available winding height. Therefore, an interleaved con-figuration that splits the winding into two portions of two layers each dissipates 30% less power than the optimal single-winding-portion configuration. This analysis can be readily extended to other interleave strategies by considering the constraint on avail-able winding height to be 1/n, where n is the number of interleaved winding portions. Resultant-loss and energy-equivalent thicknesses will respectively increase and decrease by a factor of n with appropriate inter-leaving.
When an optimal winding strategy is selected, the resultant-loss and magnetic-energy-equivalent winding thicknesses can be used to determine the normalized dissipation and energy storage for equivalent single-turn conductors. These results are readily scaled for the specific application using the square of the amp-turn product through the cross-section.
The secondary current of the bridge transformer contains a dc bias component because rectifier elements force unidirectional currents. Figs. 6 and 7 display the results for one of the half secondaries again operating at 62.5% duty cycle. The significant dc component causes thicker conductors to have greater benefit; therefore, two portions of a single layer each provide the lowest winding dissipation with a combined loss-equivalent thickness of 48%. Fig. 7 indicates that the lowest ac magnetic energy is also achieved with two single-layer portions, yielding a total magnetic-energy-equivalent thickness of 17%. Note that this equivalent thickness is correlated to the RMS current of the total waveshape, including the dc bias component.
The forward-converter application also generates a significant bias component in the current waveshape. For a duty cycle of 35.2%, Fig. 8 indicates that two portions of two layers each are the preferred choice to minimize loss with a combined loss-equivalent thickness of 40%. The harmonic distribution of the forward converter causes thick single-layer portions to be less beneficial. Clearly, optimal transformer design depends on an accurate definition of application waveshapes and constituent harmonic components.
Transformer Examples
Two transformers were designed using the methods outlined earlier. Fig. 10 summarizes total transformer dissipation at 80°C as a function of duty cycle for a bridge transformer operating at 150 kHz and providing 12 V at 60 A. Fig. 11 displays the results at 25°C for a forward transformer operating at 100 kHz and providing 20 V at 5 A.
Open-circuit test methods were used to measure core loss at each of the harmonic components of application voltage. Short-circuit test methods were used to measure ac resistance and evaluate ac winding loss at each of the harmonic components of application current. DCR test methods were used to evaluate dc loss of windings conducting bias currents. Figs. 10 and 11 summarize total dissipation using these comprehensive methods. Both transformers achieve efficiencies in excess of 99%.
References
Quinn, V. “New Technology Reduces Eddy Current Dissipation in Windings,” Properties and Applications of Magnetic Materials Conference Record, 2005.