Determine Free-Running Frequency of QR Systems
Oct 1, 2002 12:00 PM
By Christophe Basso, ON Semiconductor, France
News & Features From Auto Electronics
Committed to improving hybrid electric cars
New Motors for Hybrid Vehicles
Battery Firms Battle for Hybrid Hegemony
Innovative Bipolar Plates for Fuel Cells
See More Headlines
Top Articles
Exploring Current Transformer Applications
Ultracapacitor Technology Powers Electronic Circuits
Buck-Converter Design Demystified
Sensorless Motor Control Simplifies Washer Drives
PET Resources
Buyer's Guide
Conferences
Engineering Jobs
Power Electronics Events
Rent Our Lists
Spotlight on Digital Power
A quasi-square wave switchmode power supply offers many advantages — including a soft EMI signature and a constant efficiency over a broad output load range. However, by nature, a quasi-resonant (QR) supply exhibits a highly variable switching frequency that depends on the input/output operating conditions. Here, we will evaluate the switching frequency at a given operating point and give the designer the necessary insight to dimension his system.
A flyback supply working in the QR mode is just a standard PWM-driven flyback circuit with an added resonating tank. Fig. 1 shows the basic configuration of a converter that could be controlled through a dedicated circuit.
In Fig. 1, the resonating tank is made of Lp — Cp, the primary inductance and the resonating capacitor. When the switch closes, the current builds up in the primary inductance and the drain voltage is close to zero. At the switch opening, the primary current together with C
Fig. 2, on page 72, portrays a typical signal where the reflected voltage V
Succession of Events
To calculate the operating frequency of a QR converter, you need to account for all the parasitic elements involved in the structure. For example, the total capacitance present over the drain node plays a significant role in slowing down the drain-source signal. Neglecting it leads to a large error, especially if the resonating capacitor has been increased to reduce the dVds/dt and avoid a clamping network. To fully understand the time sequence, Fig. 3, on page 72, shows a QR converter truly operating in ZVS, with the drain-source signal Vds(t), the internal primary inductance current Iprimary(t), and the driver waveshape to detail exactly when the MOSFET is reactivated. Notice that the primary current Iprimary(t) and Vds(t) are in quadrature, switching the MOSFET when Vds(t) is minimum also engenders zero current switching (ZCS). However, if the delay between core reset detection and MOSFET reactivation is too long or too short, then ZVS/ZCS can no longer be maintained and losses increase.
Let's review the events shown in Fig. 3.
The switch closes, forcing V
Upon reaching I
Where:
I
At the switch opening, the voltage cannot instantaneously increase. The drain capacitive node must be charged with the primary current, I
If we neglect all other capacitance at the drain node, the peak voltage is given by the characteristic impedance of the resonating tank of L
The secondary diode starts to conduct when Vds(t) reaches N × (V
Where:
V
V
N = Np/Ns turn ratio
L
C
T
It can thus be defined by:
Without entering into complex calculations, we can see that the valley occurs at half the natural ringing period imposed by L
However, when using complete calculations, it shows that this result is only valid for lightly damped resonating tanks, which is often the case.
We now have everything needed to compute the switching frequency by summing up all these events and reversing the result: See Equation (8), below.
The unknown equation remains the peak current Ip. To obtain it, we need to start from the classical flyback power transfer formula:
Rearranging gives:
Plug Equation (10) into Equation (8) to obtain a third order equation for Ip: See Equation (11), below.
This third order equation can be examined with a mathematical solver to obtain a rather complicated formula:
with:
Once I
To ease work for the designer, we have entered this formula into an Excel spreadsheet, NCP1205.
Fig. 4 is a typical curve given by the spreadsheet for a 30W SMPS featuring the following component values: L
To check the calculations, we built a 30W prototype using the NCP1205, a new QR controller featuring a soft frequency foldback with a voltage controlled oscillator (VCO). Fig. 4 compares the frequency variation with the input voltage measured or calculated on the board. As you can see, both curves are in agreement and the high-line error is better than 10%, confirming our assumptions. The complete description of the board is the object of a dedicated application note.
Simplified Controller SPICE Model
The SPICE model offers all necessary features to help validate any calculations. The NCP1205 benefits from a comprehensive model declined in INTUSOFT's IsSpice but also CADENCE's PSpice. However, incorporating all the elements that make the controller precisely reflect the real part (e.g., a VCO for frequency foldback) complicates the model and hampers the simulation time.
To quickly validate and iterate component values, a simplified model has been derived. Fig. 5 depicts how to use it in a ZVS quasi-resonance configuration. The model directly drives a MOSFET and does not bother with quiescent or operating current, under voltage lockouts, etc. but simply focuses on the system: a QR configuration with a resonating capacitor C
Two simplified models are available: FreeRunDT, which integrates a programmable minimum T
As shown in Fig. 6, when all parasitic elements are correctly assessed and reflected back the model, good agreement between simulated and measured curves isn't too difficult to obtain.
The author thanks his colleagues François Lhermite and Joël Turchi for fruitful discussions related to quasi-resonant converters. Thanks also to Laszlo Huber from Delta Electronics for his comments during the experiments.
Reference
For more information on this article, CIRCLE 339 on Reader Service Card