A New Way to Model Current-Mode Control
Jun 1, 2007 12:00 PM
By Robert Sheehan, Principal Applications Engineer,National Semiconductor, Santa Clara, Calif.
Unified models using general gain parameters provide the solution for any peak- or valley-derived current-mode converter.
Click here for the enhanced PDF version of this article
including diagrams and/or equations.
News & Features From Auto Electronics
Committed to improving hybrid electric cars
New Motors for Hybrid Vehicles
Battery Firms Battle for Hybrid Hegemony
Innovative Bipolar Plates for Fuel Cells
See More Headlines
Top Articles
Exploring Current Transformer Applications
Ultracapacitor Technology Powers Electronic Circuits
Buck-Converter Design Demystified
Sensorless Motor Control Simplifies Washer Drives
PET Resources
Buyer's Guide
Conferences
Engineering Jobs
Power Electronics Events
Rent Our Lists
Spotlight on Digital Power
In Part I of this article (Power Electronics Technology, May 2007), the basic operation of current-mode control was broken down into its component parts, allowing a greater intuitive understanding for the practical designer. A comparison of the modulator gain was made to voltage-mode operation, and a simple analogy showed how the optimal slope-compensation requirement could be obtained without any complicated equations.
Now unified models using general gain parameters are introduced, along with simplified design equations, and an in-depth treatment of the analysis and theory is presented. This general modeling technique explains how previous models can complement each other on various aspects of the current-mode-control theory.
Modeling Continuous-Conduction Mode
This article provides models and solutions for fixed-frequency, continuous-conduction-mode (CCM) operation. Reference [1] covers the theoretical background for this subject, providing an exhaustive analysis of the buck regulator with its associated models and results. To prevent duplication, the boost regulator of Fig. 1 forms the basis for the discussion here. A more rapid approach to using this information is to bypass reference [1] and follow the general guidelines for slope compensation described in the first part of this article. Then the simplified equations can be used to determine the frequency response.
A current-mode switching regulator is a sampled-data system, the bandwidth of which is limited by the switching frequency. Beyond half the switching frequency, the response of the inductor current to a change in control voltage is not accurately reproduced. To quantify this effect for linear modeling, the continuous-time model of reference [2] successfully placed the sampling-gain term in the closed-current feedback loop. This allows accurate modeling of the control-to-output transfer function using the term H
To accurately model the current loop, the unified model of reference [3] placed the sampling-gain term in the forward path. For peak or valley current modes with a fixed slope-compensation ramp, this also accurately models the control-to-output transfer function using the term F
To develop the theory for emulated current-mode control, reference [1] used a fresh approach, deriving general gain parameters, which are consistent with both models. In addition, a new representation of the sampling-gain term for the closed-current loop was developed, identifying limitations of the forward-path sampling-gain term.
The upper circuit in Fig. 2 represents the unified form of the model, with K being the feed-forward term. In the lower circuit, K
where T is the switching period. The term K
but this serves no purpose, because Q
To place either sampling-gain term into the linear models for the buck, boost and buck-boost, the following relationships are applied: F
Simplified Transfer Functions
No assumptions for simplification were made during the derivation of the transfer functions. The only initial assumptions are the ones generally accepted to be valid in a first-order analysis. Voltage sources, current sources and switches are ideal, with no delays in the control circuit. Amplifier inputs are high impedance, with no significant loading of the previous stage. Simplification of the results was made after the complete derivation, which included all terms. Reference [1] has examples for the buck regulator.
To show the factored form, the simplified transfer functions assume that the poles are well separated by the current-loop gain. Expressions for the low-frequency model do not show the additional phase shift due to the sampling effect. The control-to-output transfer function with the sampling-gain term accurately represents the circuit's behavior up to half the switching frequency. The line-to-output expressions for audio susceptibility are accurate at dc, but diverge from the actual response as frequency increases.
The current-sense gain is defined as R
To include the sampling-gain term in the control to output transfer function, the term
1+5/ω
Sampling Gain Q
Using a value of Q = 0.637 will cause any tendency toward sub-harmonic oscillation to damp in one switching cycle. With respect to the closed-current-loop control-to-output function, the effective sampled-gain inductor pole is given by:
This is the frequency at which a 45-degree phase shift occurs because of the sampling gain. For Q = 0.637, f
To determine the effect of reducing the slope compensation to increase the voltage-loop bandwidth, an emulated-peak-current-mode buck with proportional slope-compensation switching circuit was implemented in SIMPLIS. A standard type-II 10 MHz error amplifier was used for frequency compensation. With T/L = (5 µs/5 µH) and R
Linear Models
Simple, accurate and easy-to-use linear models have been developed for the buck, boost and buck-boost converter topologies. Each linear model has been verified using results from its corresponding switching model. In this manner, validation for any transfer function is possible, identifying the accuracy limit of the given linear model. General gain parameters are listed in Table 1. These parameters are independent of topology, and written in terms of the terminal voltage (V
The coefficients for the linear model of the buck regulator shown in Fig. 3 are:
The control-to-output simplified transfer function is:
and the line-to-output simplified transfer function is:
where
The coefficients for the linear model of the current-mode boost regulator shown in Fig. 4 are:
The control-to-output simplified transfer function is:
and the line-to-output simplified transfer function is:
where
The coefficients for the linear model of the current-mode buck-boost regulator shown in Fig. 5 are:
The control-to-output simplified transfer function is:
and the line-to-output simplified transfer function is:
where
Boost Regulator Simulation Example
For the peak-current-mode boost converter example, comparisons of results from the switching circuit of Fig. 1 were made to the linear model of Fig. 4 using the sampling-gain term H
The choice of simulation program is important, since not all SPICE programs calculate parameters with the same degree of accuracy. For switching-model simulation, SIMPLIS is able to produce Bode plots directly from the switching model. This program was used to produce the switching-model simulation results. The low-frequency model was made with SIMetrix, which is the general-purpose simulator for the SIMetrix/SIMPLIS program. This simulator only handles Laplace equations for s in numerical form, where the numerator order must be equal to or less than the denominator order. PSpice is much better suited for linear models with Laplace functions in parameter form. It is more accurate than the SIMetrix/SIMPLIS program but cannot produce Bode plots directly from the switching model. PSpice or a program with similar capability may be used to obtain the simulation results for the linear model.
Unified Modulator Modeling
In Part I of this article, the criteria for current-mode control was considered. This led to the linear model, with the gain terms being easily identified. The importance of the concept of K
A new closed-current-loop sampling-gain term has been defined that accommodates any fixed-frequency peak- or valley-derived operating mode. Limitation of the forward-sampling-gain term has been identified, providing direction for further development in linear modeling.
References
Sheehan, Robert, “Emulated Current Mode Control for Buck Regulators Using Sample and Hold Technique,” Power Electronics Technology Exhibition and Conference, PES02, October 2006. An updated version of this paper, which includes complete appendix material, is available from National Semiconductor Corp.
Ridley, R.B., “A New, Continuous-Time Model for Current Mode Control,” IEEE Transactions on Power Electronics, Vol. 6, Issue 2, pp. 271-280, 1991.
Tan, F.D. and Middlebrook, R.D., “A Unified Model for Current-Programmed Converters,” IEEE Transactions on Power Electronics, Vol. 10, Issue 4, pp. 397-408, 1995.